Test report No 381211/13975/CPR dated 25 March 2021 Page 3 of 3 Environmental conditions Tem erature (15 ± 1) °C Relative humidity (50 ± 5) % Results Laminated glass Measured thickness Dro height Im acts Result [No ] [mm] [m] [No ] 1 8,42 1,50 3 no penetration 2 8,61 1,50 3 no penetration 3 8,60 1,50 3 no penetration Photogra hs of a s ecimen before and after the test Findings The item meets the requirements of clause 10 1 “Prova di caduta” ( Drop test”) of standard UNI EN 356:2002 and in accordance with table 4 “Tabella di classificazione per la resistenza delle vetrazioni di sicurezza” ( Classification table for the resistance of safety glazing”) may therefore be awarded the following category of resistance EN 356 P1A Chief Test Technician (Dott Andrea Bruschi) Head of Security and Safety Laboratory (Dott Andrea Bruschi) Technical Manager (Dott Ing Giuseppe Persano Adorno)